vmg16 e, Alarmy, domofony, P.Poż, Satel

Nie obrażaj więc mojej inteligencji poprzez czynione na pokaz zaniżanie własnej.
®
VOICE MESSAGE GENERATOR
VMG-16
vmg16_e 08/05
The VMG-16 Voice Message Generator is designed for playback (reproduction) of
prerecorded messages. It can work in conjunction with the CA-64 and INTEGRA series alarm
control panels as an output expander, as well as with any other equipment capable of
controlling the generator inputs.
1. Description of electronics board
Fig. 1. Schematic view of VMG-16 voice message generator board.
Legend:
1 –
package of DIP-switches
– setting individual module address and module operating
options (see: DIP-
SWITCHES
).
2 –
REC
button
– recording messages;
3 –
PLAY
button
– playing back recorded messages;
4 –
NEXT
button
– switching between successive messages;
5 –
microphone
;
6 –
LED
indicators
(see: LED
SIGNALING
):
M0…M3
- message number;
PLAY
- message playback;
REC
- message recording;
ME
- message memory full;
EA
- supply / communication with control panel.
7 –
LINE
socket
– connecting headset or external audio
amplifier.
Fig. 2. Set of LEDs on
electronics board
2
SATEL
VMG-16
Description of terminals:
+12V
– power supply input.
COM
– common ground.
IN1…IN16
– inputs to generate corresponding messages (interaction with any device).
TMP
– tamper input (NC).
CLK
,
DAT
– communication bus terminals.
A RS485 B
– RS-485 port terminals;
SPEAKER
– terminals for connecting 8Ω loudspeaker. Output power regulated up to 6W.
1.1 DIP-switches
Fig. 3. DIP-switches with descriptions as indicated on the electronics board.
The switches 1 to 5
are used for setting the module address. The address, which is
indispensable for the VMG-16 generator to interface with the CA-64 / INTEGRA control
panels, must differ from the addresses of the other modules connected to the expander bus
of the control panel. In order to determine the expander address, sum up the values set on
particular switches, according to Table 1.
Switch number
1
2
3
4
5
Numerical value
(for switch in ON position)
1
2
4
8
16
Table 1.
The five switches enable addresses to be assigned to 32 expanders (numbers from 0 to 31).
Addresses of the expanders connected to one bus may not repeat, while the addressing
order can be random. It is recommended that you assign consecutive addresses, starting
from zero, to expanders and modules to be connected to one bus. Thus you can prevent any
problems from arising during expansion of the system.
When the generator is not used with the CA-64 or INTEGRA alarm control panels, position of
the switches 1-5 is unimportant.
The switch 6
makes it possible to select the message length: either fixed (the switch in OFF
position) or variable (the switch in ON position). In the case of fixed length messages, up to
16 messages of 15-second duration can be recorded. In the case of variable length
messages, the total duration of recorded messages may not exceed 4 minutes.
The switch 7
relates only to operation with the CA-64 / INTEGRA control panels. It is used
for determination of the number of messages to be played back by the generator: 16 (the
switch in OFF position) or 8 (the switch in ON position). The VMG-16 generator to play back
8 messages will be identified in the system as one output expander and will take one
address. The VMG-16 generator to play back 16 messages will be identified in the system as
two output expanders and will take 2 addresses. This should be borne in mind when
VMG-16
SATEL
3
addressing the module, because the other address to be assigned to the generator is the one
set on the switches + 1 (if the address 31 is set on the switches, the other address assigned
to the generator will have the value 0). If this address is already taken, the control panel will
be unable to properly complete the identification.
The switch 8,
when in the ON position, enables recording of messages. When in the OFF
position, it disables the message recording feature.
address:
20
message length:
fixed
recording:
possible
number of messages:
16
Fig. 4. Example of setting the DIP-switches for interaction with CA-64 or INTEGRA control
panels.
1.2 LED signaling
The LED indicators designated M0, M1, M2 and M3 inform which message is currently being
recorded / played back. Switching to the next message is done by means of the NEXT
button. You can determine the m
essage number by using Ta
ble 2.
LED indicator
Message number
M3 M2 M1 M0
1
- LED "off"
2
3
- LED "on"
4
5
6
7
8
9
10
11
12
13
14
15
16
Table 2.
4
SATEL
VMG-16
The LED designated PLAY is ON when the message is being played back.
The LED designated REC is ON when the message is being recorded.
The LED designated ME is ON when the VMG-16 generator operates in the mode of
handling variable-length messages, and the module message memory is full.
The LED designated EA goes ON after power-up. When working in conjunction with the CA-
64 / INTEGRA control panels, the LED is blinking with a changing frequency to indicate
communication (it is ON when the module has failed to be identified in the system, or when
the STARTER program is running).
Additionally, the LEDs serve as volume level indicators of the messages being played back
(see: V
OLUME LEVEL CONTROL
). Level 1 is indicated by the M3 LED being "ON", Level 2 - by
the M3 and M2 LEDs being "ON", etc., until Level 8, when all the LEDs are "ON".
2. Installation and startup of the VMG-16 module
All connections are to be made with power supply disconnected.
2.1 Interacting with CA-64 / INTEGRA alarm control panels
1. Using the DIP-switches, set the corresponding address and options related to the module
operation.
2. Connect the CLK, DTA and COM terminals with cables to the expander bus on the control
panel main board.
3. Connect the loudspeaker to the SPEAKER terminals, or the audio amplifier / headset to
the LINE socket, as may be required.
4. Connect the housing tamper contact cables to the TMP and COM terminals. If no tamper
contact is to be connected to the TMP input, short-circuit the TMP terminal to the COM
ground.
5. Connect the module supply cables to the +12V and COM terminals. The generator supply
voltage is not necessarily be provided from the control panel main board. A power supply
unit or another expander with power supply can be used for this purpose.
6. Turn on power supply of the security alarm system. The LED designated EA will come on.
7. Start the E
XPANDER IDENTIFICATION
function in the LCD keypad (
Æ
S
ERVICE MODE
Æ
S
TRUCTURE
Æ
H
ARDWARE
Æ
I
DENTIFICATION
). The identification completed, the EA LED
will start blinking.
8. Program suitably the alarm system outputs assigned to the expander:

select the output reaction type, i.e. define the circumstances when the message will be
played back;

enable the "Polarization" option.
Note:
The message will be played back once, irrespective of the ON-time of the control
panel output. If the message is to be played back repeatedly, the "Pulsation" option
should be enabled for the output.
9. Quit the S
ERVICE MODE
and save the changes to the control panel memory.
2.2 Interacting with any control device
1. Using the DIP-switches, set the options related to the module operation.
2. Connect the generator inputs with cables to the control device outputs.
3. Connect the loudspeaker to the SPEAKER terminals, or the audio amplifier / headset to
the LINE socket, as required.
VMG-16
SATEL
5
4. Connect the module supply cables to the +12V and COM terminals. The supply voltage
can be provided from control device or any power supply unit with 12V DC output voltage.
5. Turn power supply on. The LED designated EA will come on.
3. Operating the voice message generator
3.1 Recordingmessages
Depending on the settings of DIP-switches, 8 or 16 messages with a fixed or variable length
can be recorded.
In order to record a message, you should:
1. Set the switch 8 in ON position.
2. Using the NEXT button, select the number of message to be recorded (the number is
displayed on the M3…M0 LEDs).
3. Press and hold down the REC button. The REC LED will go on.
4. Say the message words.
5. Release the REC button. The REC LED will go off.
Notes:

In the fixed length message handling mode (DIP-switch 6 in OFF position), when the
recording time exceeds 15 seconds, the recording will be stopped automatically.

Changing the generator from the fixed length message handling mode to the variable
length message handling mode (or the other way round) will require re-recording of all the
messages.

In the variable length message handling mode, replacement of any message with another
one (having a different length) will make it necessary to re-record all the subsequent
messages.
3.2 Playing back messages
If the VMG-16 generator operates in conjunction with the CA-64 / INTEGRA control panel as
an output expander, the messages are played back when the corresponding output of the
security system is activated: the 1
st
message on activating the first in turn expander output,
the 2
nd
one on activating the second in turn expander output, etc.
If the VMG-16 generator works in conjunction with another control device (e.g. another alarm
control panel), the messages are played back after ground voltage (0V) is fed to the
corresponding generator input, the 1
st
message on feeding the ground voltage to the IN1
input, the 2
nd
message on feeding the ground voltage to the IN2 input, etc. The inputs are
dedicated to interface with the OC type outputs .
The VMG-16 generator enqueues up to 32 commands to play back voice messages.
The playback can be started manually. To do so, press the NEXT button to select the number
of the message to be played back and press the PLAY button (the PLAY LED will go on).
Note:
If the VMG-16 generator is working in the variable length message mode and some
messages are still to be recorded, an attempt to play back the non-existent messages
will result in starting the first message.
  • zanotowane.pl
  • doc.pisz.pl
  • pdf.pisz.pl
  • alter.htw.pl
  • Powered by WordPress, © Nie obrażaj więc mojej inteligencji poprzez czynione na pokaz zaniżanie własnej.